The capacitive Coupling-/Decoupling Networks CDN 2402/2410 are used in combination with the Multi-CE5 and allows superimposition of surge and burst test pulses to up to four I/O signal lines. The test set-up is suitable for surge immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.
Coupling network (CDN)
CDN 2410
Short informations
| Data- / signal lines |
| Surge: 2.5 kV, 1.2/50 μs |
| Burst: 2.5 kV , 5/50 ns |
| Typ. 240V≈ |
Additional Info
- IEC: IEC 61000-4-04, IEC 61000-4-05
- CDN usage: Burst (EFTG), Surge (CWG), Data- / signal lines